Fluke MET/CAL Procedure ============================================================================= INSTRUMENT: Transmation 1045: (1 year) CAL VER /5500,34401 DATE: 11-Sep-97 AUTHOR: Fluke Corporation REVISION: $Revision: 1.4 $ ADJUSTMENT THRESHOLD: 70% NUMBER OF TESTS: 16 NUMBER OF LINES: 106 CONFIGURATION: Fluke 5500A CONFIGURATION: HP 34401A ============================================================================= # # INPUT LOpatibility: # 5500/CAL 4.0 or MET/CAL 4.0 or later. # # Subprocedures: # None # # Required Files: # None # # System Specifications: # TUR calculation is based on specification interval of the accuracy file. # The default 5500A accuracy file contains 90 day specs. # # Fluke makes no warranty, expressed or implied, as to the fitness # or suitability of this procedure in the customer's application. # STEP FSC RANGE NOMINAL TOLERANCE MOD1 MOD2 3 4 CON 1.001 ASK- R P F V 1.002 ASK+ K X 1.003 HEAD PRELIMINARY INSTRUCTIONS 1.004 DISP Connect UUT to wall power adaptor and turn unit ON. 1.004 DISP 1.004 DISP Warm-up time: 30min - REQUIRED 1.004 DISP Temperature: 23 +/-2 degC 1.004 DISP Humidity: <75% 1.005 DISP [32] WARNING 1.005 DISP HIGH VOLTAGE is used or exposed during the performance 1.005 DISP of this calibration. DEATH ON CONTACT may result if 1.005 DISP personnel fail to observe safety precautions. 1.006 DISP This procedure requires a 4 1/2 digit DMM. 1.007 HEAD INITIAL SETUP 1.008 DISP Set DISPLAY MODE to IN. 1.009 HEAD {mV INPUT} 1.010 DISP Set INPUT to mV. 1.011 DISP Connect the 5500A to the UUT as follows: 1.011 DISP [32] 5500A NORMAL HI to UUT mV INPUT HI 1.011 DISP [32] 5500A NORMAL LO to UUT mV/V INPUT LO 1.012 HEAD mV INPUT: {100mV Range} 1.013 5500 100 -99.00mV 0.01% 0.02U 2W 2.001 5500 100 00.00mV 0.01% 0.02U 2W 3.001 5500 100 99.00mV 0.01% 0.02U 2W 4.001 HEAD {V INPUT} 4.002 DISP Connect the 5500A to the UUT as follows: 4.002 DISP [32] 5500A NORMAL HI to UUT V INPUT HI 4.002 DISP [32] 5500A NORMAL LO to UUT mV/V INPUT LO 4.003 HEAD V INPUT: {10V Range} 4.004 DISP Set INPUT to 10V. 4.005 5500 10 -9.900V 0.01% 0.002U 2W 5.001 5500 10 0.000V 0.01% 0.002U 2W 6.001 5500 10 9.900V 0.01% 0.002U 2W 7.001 HEAD V INPUT: {50V Range} 7.002 DISP Set INPUT to 50V. 7.003 5500 50 -49.90V 0.01% 0.02U 2W 8.001 5500 50 0.00V 0.01% 0.02U 2W 9.001 5500 50 49.90V 0.01% 0.02U 2W 10.001 HEAD {mA INPUT} 10.002 DISP Set INPUT to mA. 10.003 DISP Connect the 5500A to the UUT as follows: 10.003 DISP [32] 5500A AUX HI to UUT mA INPUT HI 10.003 DISP [32] 5500A AUX LO to UUT mA INPUT LO 10.004 HEAD mA INPUT: {50mA Range} 10.005 5500 50 -49.90mA 0.01% 0.02U 2W 11.001 5500 50 0.00mA 0.01% 0.02U 2W 12.001 5500 50 49.90mA 0.01% 0.02U 2W 13.001 DISP Disconnect the 5500A from the UUT. 13.002 HEAD {mV OUTPUT} 13.003 DISP Turn the UUT OFF. 13.004 DISP Connect the 34401A to the UUT as follows: 13.004 DISP [32] 34401A INPUT HI to UUT mV OUTPUT 13.004 DISP [32] 34401A INPUT LO to UUT OUTPUT LO 13.005 DISP Set DISPLAY MODE to OUT. 13.005 DISP Set OUTPUT to mV. 13.006 DISP Turn the UUT ON. 13.007 DISP Adjust for an output of 99.90mV using the COARSE and 13.007 DISP FINE ADJUST controls (as measured on the DVM). 13.008 34401 99.90mV 0.03U 2W 14.001 HEAD {V OUTPUT} 14.002 DISP Connect the 34401A to the UUT as follows: 14.002 DISP [32] 34401A INPUT HI to UUT V OUTPUT 14.002 DISP [32] 34401A INPUT LO to UUT OUTPUT LO 14.003 DISP Set OUTPUT to 10V. 14.004 DISP Adjust for an output of 9.900V using the COARSE and 14.004 DISP FINE ADJUST controls (as measured on the DVM). 14.005 34401 9.900V +.002U -.003U 2W 15.001 HEAD {mA OUTPUT} 15.002 DISP Connect the 34401A to the UUT as follows: 15.002 DISP [32] 34401A 3A INPUT to UUT mA OUTPUT 15.002 DISP [32] 34401A INPUT LO to UUT OUTPUT LO 15.003 DISP Set OUTPUT to mA. 15.004 DISP Adjust for an output of 20.00mA using the COARSE and 15.004 DISP FINE ADJUST controls (as measured on the DVM). 15.005 34401 20.00mA 0.02U 2W 16.001 END